Checking The Wiring And Terminals
Under no circumstances use an ohmmeter or other live measuring instrument to take readings on a disconnected, non-deployed, pyrotechnical inflatable curtain. his could deploy the inflatable curtain
- Ignition off, wait for 15 seconds.
- Disconnect the connector for Supplemental restraint system module (SRS).
- Disconnect the connector from the right-hand inflatable curtain.
HINT: Check if other diagnostic trouble codes (DTCs), that indicate another activatable collision protection system, are stored.
HINT: The fault is due to a short-circuit to another circuit in the activatable collision protection system.
Check connectors for damage to pins and connections.
Also check other connectors and terminals that connect the wiring between the Supplemental restraint system module (SRS) and the inflatable curtain.
NOTE:The connector to the activatable collision protection system in the other circuit must be disconnected before a reading is taken.
Check the cable. Check for a short-circuit to another circuit with activatable collision protection system. he resistance reading should read infinite resistance.
Take readings between:
- The connector to the right-hand inflatable curtain terminal #1 and the connector to the other activatable collision protection system terminals #1 and #2.
- The connector to the right-hand inflatable curtain terminal #2 and the connector to the other activatable collision protection system terminals #1 and #2.
Remedy as necessary.
Other information
- Continue
Refer to POWERING THE SRS SYSTEM