Checking the Relay And Supply
Check that relay 2/90 is correctly connected. Check that the relay is not defective.
HINT: This tip applies only in the event of an open-circuit in cable.
HINT: The fault may have been caused by an open-circuit in the supply to the relay. The voltage must be 12 V at terminal #1 for relay 2/90. Check fuse 11B/13 in particular.
Remedy as necessary.
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the Cable