Intermittent fault
- Ignition off.
Check the control module and transmission input speed sensor connectors. Check for contact resistance and oxidation according to Contact resistance and oxidation .
Check the power supply cable between control module terminal #A59 (#A59) and transmission connector terminal #A2. Check for an intermittent open-circuit according to Open-circuit, intermittent faults . Check for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
Check the signal cable between control module terminal #A41 (#A41) and transmission connector terminal #A1. Check for an intermittent open-circuit according to Open-circuit, intermittent faults . Check for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the control module, see Transmission control module (TCM), replacing
- To disconnect the transmission connector, see Connectors, transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
- Continue
Refer to Information