Removal & Installation
- Remove air cleaner housing intake pipe from connection above radiator and twist upward. Remove canister purge valve from fan shroud. Remove cable from clamp.
- Remove air pipe at control module box. Disconnect hose clamp and charge air pipe (if applicable) on right side. Use a hot air gun if necessary.
- Remove MAP sensor from mount in front cover plate. Remove tie straps holding wiring on upper fan shroud and remove wiring.
- Lift out hose for expansion tank. Disconnect both cooling fan connectors.
- Remove upper oil cooler hose at cooling unit and move aside. Seal opening to avoid fluid spills.
- Remove screws holding fan shroud and carefully lift cooling fan up and out.
- Place cooling fan on a flat surface with pulley facing down. Remove cable and connector from holder on shroud.
- Remove screws holding control module and blower motor. Lift shroud off and remove control module. See Fig 1.
- Install in reverse order.
Courtesy of VOLVO CARS OF NORTH AMERICA.