Inspection Procedure
NOTE:
When replacing the master cylinder solenoid, perform zero point calibration (See CALIBRATION
).
- INSPECT A-TRAC SWITCH
- Remove the A-TRAC switch.
- Disconnect the A-TRAC switch connector.
- Measure the resistance.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Switch Condition Specified Condition 3-4 Released 10 kΩ or higher 3-4 Pushed in Below 1 Ω
NG: REPLACE A-TRAC SWITCH
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - A-TRACK SWITCH)
- Disconnect the skid control ECU connector.
- Disconnect the A-TRAC connector.
- Measure the resistance.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition A4-44 (HDCS) - E15-4 Below 1 Ω A4-44 (HDCS) - Body ground 10 kΩ or higher E15-4 - Body ground Below 1Ω
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)
- Disconnect the skid control ECU connector.
- Disconnect the combination meter connector.
- Measure the resistance.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition A4-33 (HDCW) - E14-9 Below 1 Ω A4-33 (HDCW) - Body ground 10 kΩ or higher
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT COMBINATION METER ASSEMBLY
- Check the combination meter system (See TERMINALS OF ECU
).
OK:
Combination meter is normal.
NG: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
OK: REPLACE MASTER CYLINDER SOLENOID (See DISASSEMBLY )
- Check the combination meter system (See TERMINALS OF ECU
).