Charging System: Generator: Inspection
- INSPECT ROTOR
- Check the rotor for open circuit.
Using an ohmmeter, check that there is continuity between the slip rings.
Standard resistance: 1.5 to 1.9 & Ω at 20° C (68° F)
If there is no continuity, replace the rotor.
- Check the rotor for ground.
Using an ohmmeter, check that there is no continuity between the slip ring and rotor. If there is continuity, replace the rotor.
- Check that the slip rings are not rough or scored. If rough or scored, replace the rotor.
- Using vernier calipers, measure the slip ring diameter.
Standard diameter: 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter: 14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the rotor.
- Check the rotor for open circuit.
- INSPECT BRUSHES
Using vernier caliper, measure the exposed brush length.
- Standard exposed length: 10.5 mm (0.413 in.)
- Minimum exposed length: 4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the brushes and the brush holder assembly.
- INSPECT BEARING
Check the bearing is not rough or worn.
If necessary, replace the bearing (See REPLACEMENT ).