Operation Table of Solenoid Valves and Stepper Motor
WARNING: This page is about a different variant/trim than selected.
SOLENOID VALVES AND STEPPER MOTOR CHART
| Line pressure control solenoid valve | Secondary pressure control solenoid valve | TCC solenoid valve | Lock-up/select switching solenoid valve | Stepper motor | |||
|---|---|---|---|---|---|---|---|
| P or N (In 5 sec. after shifting to "P" or "N" range) | ◦ | ◦ | x | ◦ | ◦ | ||
| P | ◦ | x | x | x | x | ||
| R | ◦ | ◦ | ◦ | x | ◦ | ||
| N | ◦ | x | x | x | x | ||
| D | ◦ | ◦ | ◦ | x | ◦ | ||
| M | ◦ | ◦ | ◦(1) | x | ◦ | ||
| ◦: Operate x: Not operate |
|||||||
|
|||||||
VALVE STATUS CHART
| Valve status | ||
|---|---|---|
| Operate | Not operate | |
| Line pressure control solenoid valve | Close | Open |
| Secondary pressure control solenoid valve | Close | Open |
| TCC solenoid valve | Open | Close |
| Lock-up/select switching solenoid valve | Open | Close |