Fail-Safe Table
WARNING: This page is about a different variant/trim than selected.
This function is provided by the safe mechanism that assures safe driveability even when the solenoid valve, sensor or its circuit fails. The following table shows the fail-safe function for each fail condition of solenoid valve, sensor or its circuit.
DTC REFERENCE
| DTC | DTC name | Fail-safe operation |
|---|---|---|
| P0602 | Control Module Programming Error | - |
| P062F | Internal Control Module EEPROM Error | - |
| P0641 | Sensor Reference Voltage "A" Circuit/Open | - |
| P0703 | Brake Switch "B" Circuit | TCM controls actuators assuming that brake light switch is always on. |
| P0705 | Transmission Range Sensor "A" Circuit (PRNDL Input) |
|
| P0707 | Transmission Range Sensor "A" Circuit Low | |
| P0711 | Transmission Fluid Temperature Sensor "A" Circuit Range/Performance | TCM controls actuators assuming that CVT fluid temperature is specified value. |
| P0712 | Transmission Fluid Temperature Sensor "A" Circuit Low | |
| P0713 | Transmission Fluid Temperature Sensor "A" Circuit High | |
| P0716 | Input/Turbine Speed Sensor "A" Circuit Range/Performance |
|
| P0717 | Input/Turbine Speed Sensor "A" Circuit No Signal | |
| P0721 | Output Speed Sensor Circuit Range/Performance |
|
| P0722 | Output Speed Sensor Circuit No Signal | |
| P0741 | Torque Converter Clutch Circuit Performance or Stuck Off | TCM stops lock-up control operation. |
| P0776 | Pressure Control Solenoid "B" Performance/Stuck Off | - |
| P0777 | Pressure Control Solenoid "B" Stuck On | TCM transmits torque request signal to ECM (torque reduction). |
| P0826 | Up and Down Shift Switch Circuit | TCM stops manual shift mode control. |
| P0842 | Transmission Fluid Pressure Sensor/Switch "A" Circuit Low |
|
| P0843 | Transmission Fluid Pressure Sensor/Switch "A" Circuit High | |
| P0847 | Transmission Fluid Pressure Sensor/Switch "B" Circuit Low |
|
| P0848 | Transmission Fluid Pressure Sensor/Switch "B" Circuit High | |
| P0871 | Transmission Fluid Pressure Sensor/Switch "C" Circuit Range/Performance |
|
| P0961 | Pressure Control Solenoid "A" Control Circuit Range/Performance |
|
| P0962 | Pressure Control Solenoid "A" Control Circuit Low | TCM maximizes line pressure value (duty 0%). |
| P0963 | Pressure Control Solenoid "A" Control Circuit High | |
| P0966 | Pressure Control Solenoid "B" Control Circuit Low | TCM maximizes secondary pressure value (duty 0%). |
| P0967 | Pressure Control Solenoid "B" Control Circuit High | |
| P1706 | Torque Request Communication Error from TCM | - |
| P1810 | Lockup/Select Control Circuit | TCM controls actuators assuming that lock-up/select switching solenoid valve is OFF. |
| P1816 | Stepper Motor Circuit Malfunction |
|
| P1818 | Stepper Motor Performance | - |
| P1824 | External ROM No Read | TCM controls actuators assuming that secondary pressure is specified pressure. |
| P1825 | External ROM Verification Error | TCM controls actuators assuming that secondary pressure is specified pressure. |
| P1970 | Sensor Ground Circuit Malfunction |
|
| P2763 | Torque Converter Clutch Pressure Control Solenoid Control Circuit High | TCM stops lock-up operation. |
| P2764 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Low | |
| U0073 | Control Module Communication Bus Off | - |
| U0100 | Lost Communication With ECM |
|
| U0121 | Lost Communication With ABS | - |
| U0140 | Lost Communication With BCM | - |