DTC B2277: Submerging Circuit
DTC detecting condition:
Submersion circuit monitor result ON continues for 300 seconds.
Trouble symptom:
- The ignition can be turned ON, but cannot be turned OFF.
- Engine will not start.
- For replacement procedure of keyless access control module, refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
- Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>GENERAL DESCRIPTION>CAUTION
- CHECK LAN SYSTEM
.
Perform the diagnosis for LAN system. Ref. to LAN SYSTEM (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE
Is the check result OK?
Yes : Go to 2.
No : Perform the inspection according to the diagnosis for LAN system.
- CHECK SUBMERSION CONDITION
.
Check the keyless access control module and environment of equipment, and check the harness for any trace of water submersion.
Is there any trace of water submersion?
Yes : Take necessary measures against water submersion and replace the keyless access control module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE>REMOVAL
No : Replace the keyless access control module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE>REMOVAL