DTC B2271: IGN Relay Control Circuit
DTC detecting condition:
When the system judges the malfunction (difference between output value and monitoring result) 3 times continuously, during power supply status transition from ACC ON → ignition switch ON (initial check), or with 1-second interval check while the ignition switch is ON (periodical check).
Trouble symptom:
Not all functions operate at IGN ON.
Wiring diagram:
- Keyless access with push button start system Ref. to WIRING SYSTEM>KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM>WIRING DIAGRAM
- DC power supply circuit Ref. to WIRING SYSTEM>POWER SUPPLY CIRCUIT>WIRING DIAGRAM
- For replacement procedure of keyless access control module, refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
- Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>GENERAL DESCRIPTION>CAUTION
- CHECK LAN SYSTEM
.
Perform the diagnosis for LAN system. Ref. to LAN SYSTEM (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE
Is the check result OK?
Yes : Go to 2.
No : Perform the inspection according to the diagnosis for LAN system.
- CHECK FUSE
.
Check the fuse. Ref. to WIRING SYSTEM>KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM>WIRING DIAGRAM
Is the check result OK?
Yes : Go to 3.
No : Replace the fuse. When the replaced fuse is blown immediately, check the power supply circuit for short-circuited.
- CHECK HARNESS
.
- Disconnect the connector from the keyless access control module.
- Using a tester, measure the voltage between the keyless access control module connector and chassis ground.
Connector & terminal
(i91) No. 1 (+) - Chassis ground (-):
(i91) No. 4 (+) - Chassis ground (-):
Is the voltage 9.5 - 16 V?
Yes : Go to 4.
No : Check the power supply circuit.
- CHECK HARNESS (OPEN CIRCUIT)
.
Using a tester, measure the resistance between the keyless access control module connector and chassis ground.
Connector & terminal
(i92) No. 17 - Chassis ground:
(i91) No. 20 - Chassis ground:
Is the resistance less than 1 Ω?
Yes : Go to 5.
No : Repair or replace the open circuit of harness.
- CHECK HARNESS
.
Using a tester, measure the resistance between the keyless access control module connector and chassis ground.
Connector & terminal
(i91) No. 27 - Chassis ground:
Is the resistance 74.15 - 460.88 Ω? (At 20°C)
Yes : Go to 6.
No : Check the IG 2 relay. Go to 7.
- CHECK HARNESS
.
Using a tester, measure the resistance between the keyless access control module connector and chassis ground.
Connector & terminal
(i91) No. 28 - Chassis ground:
Is the resistance 50.87 - 72.17 Ω? (At 20°C)
Yes : Go to 8.
No : Check the IG 1 relay. Go to 7.
- CHECK RELAY
.
Perform unit inspection of the IG 1 relay and IG 2 relay. Ref. to SECURITY AND LOCKS>RELAY AND FUSE>INSPECTION>CHECK RELAY
Is the check result OK?
Yes : Go to 8.
No : Replace the relay. Ref. to SECURITY AND LOCKS>RELAY AND FUSE
- CHECK KEYLESS ACCESS CONTROL MODULE
.
- Connect the disconnected connectors.
- Using a tester, measure the voltage between the keyless access control module connector and chassis ground.
Connector & terminal
(i91) No. 27 (+) - Chassis ground (-):
(i91) No. 28 (+) - Chassis ground (-):
Does the voltage change as 1 V or less → 9.5 - 16 V according to the operation of ACC → IGN ON?
Yes : Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
No : Replace the keyless access control module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE>REMOVAL