LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Crosstrek Base, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (Plug-In Battery Charger (Diagnostics)) >> Work Support >> Operation >> Vehicle Control History Freeze Frame Data (Plug-In Control)

Vehicle Control History Freeze Frame Data (Plug-In Control)

WARNING: This page is about a different variant/trim than selected.
  1. On [Start] screen, select [Diagnosis].
  2. On [Vehicle selection] screen, enter vehicle information and select [OK].
  3. On [Main Menu] screen, select [Each System].
  4. On [Select System] screen, select [Plug-in Battery Charger].
  5. On [Select Function] screen, select [Work Support].
  6. On [Work Support] screen, select [Vehicle Ctl. Hist.].
  7. Select the item name of vehicle control history to display the freeze frame data for control.
  8. Check the output data.
Item name Item explanation
Smoothed Value of BATT Voltage Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Total Distance Traveled
Total Distance Traveled
IGB Signal Status
IGCT Signal Status
HV Battery Total Voltage
Charging Voltage for Hybrid Battery
Number of Auxiliary Battery Voltage Low during Charging
Charging Lid Switch Status
Charging Lid Lock Pin Request Status
Charging Lid Lamp Status
Charging Indicator lighting Request
AC Charging Inlet Connect Status Connection state or availability of components connected to AC charger inlet
None/Connecting Charging Connector/Temporarily Nonusable/Nonusable/Not Connect/Connector Not Engaged Properly Status
AC Charging Inlet Type Charger inlet type
None/Type1/Type2
Charging Connector Connect Status Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charging Connector Connect Status Voltage
Charging Connector Insert Status Connection state of charging connector or charger inlet
ON: Connected
OFF: Not connected
Charging Connector Lock Switch Status Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charging Connector Lock Pin Status
Charging Connector Lock Motor Unlock Direction Revolution Request Current
Charging Connector Lock Motor Lock Direction Revolution Request Current
Charging Cable Power Plug Connecting Status Connection state of electric vehicle charger cable assembly to electrical outlet
None/Connecting/Not Connect/Abnormal
Charger Power Supply Voltage Type Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charger Operation Status
Charger Operation Request
Plug-in Control ECM Start Request after Charger Connected Electric vehicle charger assembly activation request after charging cable connected
ON: Requested
OFF: Not requested
Charger Input Power Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charger Output Power
Charger Cooling Fan Drive Request
Charger Cooling Fan Driving Duty
Charger Cooling Fan Revolution
Status Charging Control for HV HV battery control state during charging
Unfixed/Preparing/Executing/End Processing
Charging Control Signal Status CPLT signal condition
None/Normal/Temporarily Nonusable/Nonusable/Stuck Low/Stuck High
Current Time (hour) Electric vehicle charger assembly current time (hour)
Current Time (sec) Electric vehicle charger assembly current time (sec)
Current Time (min) Electric vehicle charger assembly current time (min)
Current Time (day of the week) Electric vehicle charger assembly current time (day of the week)
None/Monday/Tuesday/Wednesday/Thursday/Friday/Saturday/Sunday
Gap of Current Time Difference between time recognized by ECM and current time displayed on MFD
Not Gap or Gap
Charging Permission from Hybrid Control ECM Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charging Permission Continuation Status from Hybrid Control ECM
Charging Permission Continuation Status Reset Request from Hybrid Control ECM
Total Number of AC Charging
AC Charging Total Time
Number of Charge Canceled (Power Failure) Number of times power supply to vehicle (from charging station, etc.) stopped during charging
Target Charging Power Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Target Charging Power from Charger
Charging Required Time Calculation Status from Hybrid Control ECM
Charging Required Time from Hybrid Control ECM
Charging Elapsed Time
AC Input Voltage for Monitoring
AC Input Voltage for Control
AC Input Voltage Instantaneous Value 1 for Waveform Monitoring
AC Input Voltage Instantaneous Value 2 for Waveform Monitoring
AC Input Voltage Instantaneous Value 3 for Waveform Monitoring
AC Input Voltage Instantaneous Value 4 for Waveform Monitoring
AC Input Voltage Instantaneous Value 5 for Waveform Monitoring
AC Input Voltage Instantaneous Value 6 for Waveform Monitoring
AC Input Voltage Instantaneous Value 7 for Waveform Monitoring
AC Input Voltage Instantaneous Value 8 for Waveform Monitoring
AC Input Voltage Instantaneous Value 9 for Waveform Monitoring
AC Input Voltage Instantaneous Value 10 for Waveform Monitoring
AC Input Voltage Instantaneous Value 11 for Waveform Monitoring
AC Input Voltage Instantaneous Value 12 for Waveform Monitoring
AC Input Voltage Instantaneous Value 13 for Waveform Monitoring
AC Input Voltage Instantaneous Value 14 for Waveform Monitoring
AC Input Voltage Instantaneous Value 15 for Waveform Monitoring
AC Input Voltage Instantaneous Value 16 for Waveform Monitoring
Time Cycle of Charging Voltage Zero Crossing Point
Plug-in Control ECM Voltage (+B)
Plug-in Control ECM Voltage (SMP5)
Plug-in Control ECM Voltage (VOMS5)
Plug-in Control ECM Voltage (VOM5)
Plug-in Control ECM Voltage (VOMC5)
Plug-in Control ECM System Voltage (+12.5 V)
Plug-in Control ECM System Voltage (+1.15 V)
Plug-in Control ECM System Voltage (-7.5 V)
AC Input Current
Charging Current Upper Limit
Charging Current Duty from Charger
Time Cycle of Charging Current Duty from Charger
Charging Current Limit Status from Charger
Charging Power Output Limit from Charger
Charging Power Limit (Charging Voltage Low)
Timer Charging Switch Status
Timer Charging Reserve Cancel Request
Timer Reset Request from Charger Timer cancellation request output by charging station to Electric vehicle charger assembly (due to user operation, malfunction, etc.)
ON: Requested
OFF: Not requested
Charging History Information (Combination Meter) Result of charging or power supply (combination meter)
None
During AC Charging
AC Charging Complete
AC Charge Canceled by Abnormal AC Charging Circuit
AC Charge Canceled by Hybrid Battery
AC Charge Canceled by Battery (12V)
AC Charge Canceled by User Operation
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Charger Power Supply Voltage Low
AC Charge Canceled by Abnormal Charger Power Supply Voltage
AC Charge Canceled by Hybrid Battery Thermal Keep Control Mode
Charging History Information (Latest) Result of charging or power supply (most recent)
None
During AC Charging
AC Charging Complete
AC Charge Cancelled by Hybrid Battery Temperature out of Control Range
AC Charge Canceled by Remote Engine Starter Request
AC Charge Canceled by Charging Connector Unconnected
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Battery (12V)
AC Charge Canceled by Timer Charging Reserve
AC Charge Canceled by Charger Power Supply Voltage Out of Permissible Range
AC Charge Canceled by Abnormal Charging Control Signal
AC Charge Canceled by Charger External Failure of Charger
AC Charge Canceled by Abnormal Charger
AC Charge Canceled by Abnormal Hybrid Control
AC Charge Canceled by Detected DTC
Charging History Information (before One Time) Result of charging or power supply (2nd most recent)
None
During AC Charging
AC Charging Complete
AC Charge Cancelled by Hybrid Battery Temperature out of Control Range
AC Charge Canceled by Remote Engine Starter Request
AC Charge Canceled by Charging Connector Unconnected
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Battery (12V)
AC Charge Canceled by Timer Charging Reserve
AC Charge Canceled by Charger Power Supply Voltage Out of Permissible Range
AC Charge Canceled by Abnormal Charging Control Signal
AC Charge Canceled by Charger External Failure of Charger
AC Charge Canceled by Abnormal Charger
AC Charge Canceled by Abnormal Hybrid Control
AC Charge Canceled by Detected DTC
Charging History Information (before Two Time) Result of charging or power supply (3rd most recent)
None
During AC Charging
AC Charging Complete
AC Charge Cancelled by Hybrid Battery Temperature out of Control Range
AC Charge Canceled by Remote Engine Starter Request
AC Charge Canceled by Charging Connector Unconnected
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Battery (12V)
AC Charge Canceled by Timer Charging Reserve
AC Charge Canceled by Charger Power Supply Voltage Out of Permissible Range
AC Charge Canceled by Abnormal Charging Control Signal
AC Charge Canceled by Charger External Failure of Charger
AC Charge Canceled by Abnormal Charger
AC Charge Canceled by Abnormal Hybrid Control
AC Charge Canceled by Detected DTC
Charging History Information (before Three Time) Result of charging or power supply (4th most recent)
None
During AC Charging
AC Charging Complete
AC Charge Cancelled by Hybrid Battery Temperature out of Control Range
AC Charge Canceled by Remote Engine Starter Request
AC Charge Canceled by Charging Connector Unconnected
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Battery (12V)
AC Charge Canceled by Timer Charging Reserve
AC Charge Canceled by Charger Power Supply Voltage Out of Permissible Range
AC Charge Canceled by Abnormal Charging Control Signal
AC Charge Canceled by Charger External Failure of Charger
AC Charge Canceled by Abnormal Charger
AC Charge Canceled by Abnormal Hybrid Control
AC Charge Canceled by Detected DTC
Charging History Information (before Four Time) Result of charging or power supply (5th most recent)
None
During AC Charging
AC Charging Complete
AC Charge Cancelled by Hybrid Battery Temperature out of Control Range
AC Charge Canceled by Remote Engine Starter Request
AC Charge Canceled by Charging Connector Unconnected
AC Charge Canceled by Charger Power Failure
AC Charge Canceled by Battery (12V)
AC Charge Canceled by Timer Charging Reserve
AC Charge Canceled by Charger Power Supply Voltage Out of Permissible Range
AC Charge Canceled by Abnormal Charging Control Signal
AC Charge Canceled by Charger External Failure of Charger
AC Charge Canceled by Abnormal Charger
AC Charge Canceled by Abnormal Hybrid Control
AC Charge Canceled by Detected DTC
PFC Boosting Circuit Driver Drive Status Refer to the Data Monitor.
Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Target PFC Boosting Circuit Boosted Voltage
Voltage after Boosting by PFC Boosting Circuit
Current after Boosting by PFC Boosting Circuit
PFC Boosting Circuit Current Amplitude
PFC Boosting Circuit Temperature
PFC Boosting Circuit Output Limit Status (Over Temperature)
Sub DC/DC Converter Driver Drive Status (for Charging)
DC/DC Converter Control Mode (for Charging)
Target Sub DC/DC Converter Current (for Charging)
DC/DC Converter Temperature (for Charging)
DC/DC Converter Output Limit Status (for Charging) (Over Temperature)
Sub DC/DC Converter Operation Status (for Charging)
Sub DC/DC Converter Drive Request (for Charging)
Sub DC/DC Converter Operation Permission from Hybrid Control ECM (for Charging)
Sub DC/DC Converter Operation Permission to Sub DC/DC Converter (for Charging)
Target Sub DC/DC Converter Voltage from Hybrid Control ECM (for Charging)
Target Sub DC/DC Converter Voltage (for Charging)
Target Sub DC/DC Converter Voltage to Sub DC/DC Converter (for Charging)
Sub DC/DC Converter Output Voltage (for Charging)
Sub DC/DC Converter Output Current (for Charging)
Sub DC/DC Converter Constant Current Control (for Charging)
Sub DC/DC Converter Temperature (for Charging)
Sub DC/DC Converter Stop Request (for Charging) (Over Temperature)
Plug-in Control ECM Power Supply Relay Confirmed Status Confirmation of state of IGCT SCENE relay when power supply from Electric vehicle charger assembly begins operating
(The IGCT input signal on/off state is monitored at a certain frequency and is confirmed if the same state is detected continuously.)
Unfixed or Fixed
Plug-in Control ECM Power Supply Relay Voltage Voltage at IGCT SCENE relay when power supply from Electric vehicle charger assembly begins operating
Charging Relay Connect Request in CCID Box from CCID Box Refer to the Data Monitor. Ref. to PLUG-IN BATTERY CHARGER (DIAGNOSTICS)>DATA MONITOR>LIST .
Charging Relay Connect Request in CCID Box from Plug-in Control ECM
Rush Current Prevention Resistance Relay Activate Request