LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> CLK55 >> Repair and Diagnosis >> Body & Frame >> Windows >> Doors - 209 Chassis >> Basic Knowledge >> Power windows (PW [EFH]), function - GF72.29-P-0003Q >> Notes

Power windows (PW [EFH]), function - GF72.29-P-0003Q: Notes

MODEL 209.3 /4 

Function overview 

(not on rear side windows)

Actuation via control switch 

IMPORTANT Actuation or activation via the driver-side power window switch group (S20/1) cannot be affected by the power window switch (S21/2, S21/3, S21/4).

An activation or an already active function from a power window switch (S21/2, S21/3 or S21/4) is terminated if a new request is received by the driver-side power window switch group (S20/1) for the corresponding window.

When the power window is activated again after locking up, the drive is switched off after

approx. 0.6 s, when more than two Hall sensor edge changes from the corresponding power window motor (M10/3, M10/4, M10/5 or M10/6) are not recognized.

The windows can still be opened or closed for 5 min. after switching off circuit 15 or circuit 15R as long as the doors are not opened. The valid door status (door open or closed) is transmitted to the rear SAM control module with fuse and relay module (N10/2) by the left door contact switch (S17/3) and right door contact switch (S17/4), which then relays the information to the CAN class B bus. When a door is opened, all active power window functions are terminated.

Control points for comfort functions 

Priority for power window control commands 

Priority 1: Comfort closing and opening via soft top control button (S84/10) only on model (209.4)

Priority 2 : Driver-side power window switch group (S20/1)

Priority 3: Power window switch (S21/2, S21/3 and S21/4)

Priority 4: Comfort closing and opening via transmitter key (A8/1)

Priority 5: Comfort closing and opening via recirculated air switch (N22s2) with code (581a) Automatic air conditioning or recirculated air switch (N22/7s2) with code (581b) Comfort automatic air conditioning

IMPORTANT A power window control command with higher priority is carried out if a power window function with lower priority is currently active. A lower priority power window command cannot affect an active power window function of higher priority.

If the low-priority control command continues to exist after the function with higher priority is complete, then the power window control command is ignored. The park position of the lower priority power window control command must first be detected before the corresponding function is activated.

The first power window control command with a higher priority leads to discontinuation of the function, the second actuation to activation of the function.

  Power windows (PW), location of components Model 209.3 GF72.29-P-0003-01Q 
Model 209.4 GF72.29-P-0003-01QA 
  Power window (PW), interlinkage of components Model 209.3 GF72.29-P-0003-02QA 
    Model 209.4 GF72.29-P-0003-02QB 
  Power window manual lowering, function   GF72.29-P-2008Q 
  Power window automatic lowering, function   GF72.29-P-3009Q 
  Power window comfort opening, function Model 209.3 GF72.29-P-3004Q 
Model 209.4 Comfort opening via transmitter key GF72.29-P-3004QA 
Model 209.4 Comfort opening via soft top switch GF72.29-P-3004QB 
  Power windows comfort opening via recirculated air button, function   GF72.29-P-3010Q 
  Power window manual raising, function   GF72.29-P-2007Q 
  Power window automatic raising, function   GF72.29-P-2009Q 
  Power window comfort closing, function Model 209.3 GF72.29-P-3005Q 
Model 209.4 Comfort closing via transmitter key GF72.29-P-3005QA 
Model 209.4 Comfort closing via soft top control switch GF72.29-P-3005QB 
  Power window comfort closing via recirculated air button, function   GF72.29-P-3011Q 
  Power window comfort closing via keyless go, function On vehicles with code (889) Keyless go GF72.29-P-3012Q 
  Power windows normalization, function   GF72.29-P-4003Q 
  Child safety lock, function   GF72.29-P-3008Q 
  Power window position recognition, function   GF72.29-P-4000Q 
  Power window short stroke, function   GF72.29-P-4005Q