Version Coding
Version coding allows different settings to be programmed within A/C push-button control unit. Engine version is automatically transferred from the instrument cluster to the A/C push-button control unit by the serial interface (K1). All other version coding is done using Hand-Held Tester (HHT). When performing version coding follow HHT screen prompts and select desired settings. See A/C PUSH-BUTTON CONTROL UNIT VERSION CODING table. To view and set version codes with A/C push-button control unit, perform the following procedures:
- Turn ignition on.
- Set display to read right-side "HI", left-side "LO".
- Turn ignition off.
- To access value No. 1, depress REST button and hold while turning ignition on. "P1" will flash on left-side of display. Right-side will display a numeric value (i.e. "128").
- Press the right temperature selector up or down to select proper version code.
- To enter code, press and hold EC button for longer than one second.
- To access value No. 2 press the EC button again but DO NOT hold down.
- "P2" will flash on left-side of display. Right-side will display a numeric value (i.e. "136").
- Press the right temperature selector up or down to select proper version code.
- To enter code, press and hold EC button for longer than one second.
- Turn ignition off to end version coding functions.
- Reset right and left temperature settings.
A/C PUSH-BUTTON CONTROL UNIT VERSION CODING
| Displayed On A/C Push-Button Control Unit | Preliminary Setting | ||
|---|---|---|---|
| Coupe Models | |||
| Value No. 1 | |||
| 128 | With Serial Interface K1 | ||
| + 8 | With Serial Interface K2 | ||
| + 32 | With Electric Cooling Fan | ||
| Value No. 2 | |||
| + 8 | Blower Motor Bar Graph Activated | ||
| + 16 | Refrigerant Fill Level Switched Off | ||
| + 128 | SMOG Display Turned Off | ||
| Cabriolet Models | |||
| Value No. 1 | |||
| 128 | With Serial Interface K1 | ||
| + 8 | With Serial Interface K2 | ||
| + 16 | Cabriolet Coding | ||
| + 32 | With Electric Cooling Fan | ||
| Value No. 2 | |||
| + 6 | Cabriolet Control Mode | ||
| + 8 | Blower Motor Bar Graph Activated | ||
| + 16 | Refrigerant Fill Level Switched Off | ||
| + 128 | SMOG Display Turned Off | ||