Two-Step Down Function Inspection
NOTE:
- Before inspecting the two-step down function, make sure that the two-step down function is turned on (if the two-step down function is turned off, the power window does not stop once).
- The two-step down position is adjustable within 20-100 mm {0.79-3.9 in} .
- The two-step down function does not operate while the IG-OFF timer function is activated.
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 |
NOTE:
|
Yes | Two-step down function is normal. |
| No |
|
||