LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2012 >> 6 s Touring Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 610 (On-Board Diagnostic [Advanced Keyless Entry And Push Button Start System)) >> DTC P1794:16, P1794:17 [Advanced Keyless Entry And Push Button Start System] >> Diagnostic Procedure

Diagnostic Procedure

WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
Step Inspection Action
1 PERFORM PCM DTC INSPECTION  Yes Go to the applicable DTC inspection.
(See DTC TABLE [L5] .)
(See DTC TABLE [MZI-3.7] .)
No Go to the next step
2 INSPECT FUSE 
  • Switch the ignition to off.
  • Disconnect the negative battery cable.
  • Remove the ENG+B 10 A fuse.
  • Inspect the ENG+B 10 A fuse.
  • Is there any malfunction?
Yes Replace the ENG+B 10 A fuse, then go to Step 7.
No Go to the next step.
3 INSPECT BATTERY  Yes Recharge or replace the battery, then go to Step 7.
(See BATTERY RECHARGING [L5] .)
(See BATTERY RECHARGING [MZI-3.7] .)
(See BATTERY REMOVAL/INSTALLATION [L5] .)
(See BATTERY REMOVAL/INSTALLATION [MZI-3.7] .)
No Go to the next step.
4 INSPECT GENERATOR  Yes Replace the generator, then go to Step 7
(See GENERATOR REMOVAL/INSTALLATION [L5] .)
(See GENERATOR REMOVAL/INSTALLATION [MZI-3.7] .)
No Go to the next step
5 INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION 
  • Disconnect the keyless control module connector
  • Inspect the connector and terminals (corrosion, damage, pin disconnection)
  • Is there any malfunction?
Yes Repair or replace the connector or terminals, then go to Step 7
No Go to the next step
6 INSPECT BATTERY POWER SUPPLY CIRCUIT (+B2) FOR SHORT TO GROUND OR OPEN CIRCUIT 
  • Install the ENG+B 10 A fuse.
  • Reconnect the negative battery cable
  • Measure the voltage between keyless control module terminal 1E (wiring harness-side) and body ground
  • Is there any voltage?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible short to ground or open circuit, then go to the next step.
7 VERIFY TROUBLESHOOTING COMPLETED  Yes Repeat the inspection from Step 1.
If the malfunction recurs, replace the keyless control module, then go to the next step.
(See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .)
No Go to the next step
8 VERIFY THAT NO OTHER DTCs ARE PRESENT 
  • Are any DTCs present?
Yes Go to the applicable DTC inspection.
(See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .)
No DTC troubleshooting completed.