Diagnostic Procedure
WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT ABS/TCS HU/CM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 4 |
| No | Go to the next step | ||
| 2 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 4 |
| No | Go to the next step. | ||
| 3 | INSPECT ABS DRIVER CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to the next step |
| No | Go to the next step. | ||
| 4 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 5 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed | ||
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT COMBINED SENSOR CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 6. |
| No | Go to the next step | ||
| 2 | INSPECT COMBINED SENSOR
|
Yes | Replace the combined sensor, then go to Step 6. (See COMBINED SENSOR REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 3 | INSPECT DSC HU/CM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 6. |
| No | Go to the next step. | ||
| 4 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 6. |
| No | Go to the next step | ||
| 5 | INSPECT ABS DRIVER CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to the next step |
| No | Go to the next step. | ||
| 6 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step | ||
| 7 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||