Diagnostic Procedure
DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record the FREEZE FRAME DATA on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | INSPECT TR SWITCH CONNECTOR FOR POOR CONNECTION
|
Yes | Go to the next step. |
| No | Repair terminals or replace the TR switch, then go to Step 9. (See TRANSAXLE RANGE (TR) SWITCH REMOVAL/INSTALLATION ). |
||
| 4 | INSPECT TR SWITCH
|
Yes | Go to the next step. |
| No | Replace the TR switch, then go to Step 9. (See TRANSAXLE RANGE (TR) SWITCH REMOVAL/INSTALLATION ). |
||
| 5 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to step 9. |
| No | Go to the next step. | ||
| 6 | INSPECT TR SWITCH SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Repair or replace the wiring harness for short to power supply, then go to Step 9. |
| No | Go to the next step. | ||
| 7 | INSPECT TR SWITCH SIGNAL CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for open circuit, then go to step 9. | ||
| 8 | INSPECT TR SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for open circuit, then go to the next step. | ||
| 9 | VERIFY TROUBLESHOOTING OF DTC P0708 COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION ). |
| No | No concern is detected. Go to the next step. | ||
| 10 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. |
| No | DTC troubleshooting completed. | ||