System Operation Check
NOTE:
Always cycle ignition on and off before starting tests to ensure vent solenoid and compressor "on times" are reset.
- Set vehicle ride height to specification. Briefly start and run engine. Apply a load of 300-350 lbs. (136-159 kg) to the rear of the vehicle. There should be a 7-13 second delay before the compressor turns on and rear of vehicle starts to rise.
- Vehicle should rise to within 1/2" (13 mm) of ride height set in step 1) by the time the compressor shuts off. If vehicle does not rise to within 1/2" (13 mm) of the unloaded specification, check trunk for overloading. If overloaded, remove load and retest.
- Remove load applied in step 1). There should be a 7-13 second delay before vehicle starts to lower. Vehicle should lower to within 1/2" (13 mm) of ride height specification. If not, refer to DIAGNOSTIC TESTING in this article.