Retract Switch
Inspect the retract switch continuity. See CONNECTOR IDENTIFICATION . See INSPECTING RETRACT SWITCH CONTINUITY table. If continuity is as specified, inspect the switch circuit. If continuity is not as specified, replace the faulty switch located on the lower No. 1 panel of the instrument panel. See INSTRUMENT PANEL under REMOVAL & INSTALLATION in INSTRUMENT PANEL article in ACCESSORIES & EQUIPMENT.
INSPECTING RETRACT SWITCH CONTINUITY
| Switch Position | Tester Connection (Symbol), Wire Color | Specified Condition |
|---|---|---|
| RETURN | 1 (B) - 5 (MF), Gray - Red | Continuity |
| RETURN | 2 (MR) - 4 (E), Blue - White/Black | Continuity |
| RETRACT | 1 (B) - 2 (MR), Gray - Blue | Continuity |
| RETRACT | 4 (E) - 5 (MF), White/Black - Red | Continuity |