Diagnosis Procedure
- INSPECTION START
Perform inspection in accordance with procedure that confirms DTC.
Which procedure confirms DTC?
DTC confirmation procedure 1
GO TO STEP 2 .
DTC confirmation procedure 2
GO TO STEP 6 .
- CHECK DTC OF TCM
Check DTC in "Self Diagnostic Result" mode of "TCM" using CONSULT.
Is DTC detected?
YES
Perform the trouble diagnosis related to the detected DTC. Refer to DTC INDEX .
NO
GO TO STEP 3 .
- CHECK BCM INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between BCM harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)BCM Connector Terminal M71 102 Ground Selector lever P or N position 12 Other than above 0
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 5 .
- REPLACE BCM
- Replace BCM. Refer to REMOVAL AND INSTALLATION .
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
INSPECTION END
- CHECK BCM INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Disconnect A/T assembly connector.
- Check continuity between A/T assembly harness connector and BCM harness connector.
A/T assembly BCM Continuity Connector Terminal Connector Terminal F51 9 M71 102 Existed - Check continuity between A/T assembly harness connector and ground.
A/T assembly Ground Continuity Connector Terminal F51 9 Not existed
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
Repair or replace harness.
- CHECK A/T SHIFT SELECTOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect A/T shift selector (detention switch) connector.
- Check voltage between A/T shift selector (detention switch) harness connector and ground.
(+) (-) Voltage (V)
(Approx.)A/T shift selector (detention switch) Connector Terminal M57 13 Ground 12
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
GO TO STEP 7 .
- CHECK A/T SHIFT SELECTOR POWER SUPPLY CIRCUIT
- Disconnect BCM connector.
- Check continuity between A/T shift selector (detention switch) harness connector and BCM harness connector.
A/T shift selector (detention switch) BCM Continuity Connector Terminal Connector Terminal M57 13 M71 104 Existed - Check continuity between A/T shift selector (detention switch) harness connector and ground.
A/T shift selector (detention switch) Ground Continuity Connector Terminal M57 13 Not existed
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair or replace harness.
- REPLACE BCM
- Replace BCM. Refer to REMOVAL AND INSTALLATION .
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
INSPECTION END
- CHECK A/T SHIFT SELECTOR CIRCUIT
- Disconnect BCM connector and IPDM E/R connector.
- Check continuity between A/T shift selector (detention switch) harness connector and BCM harness connector.
A/T shift selector (detention switch) BCM Continuity Connector Terminal Connector Terminal M57 14 M68 37 Existed - Check continuity between A/T shift selector (detention switch) harness connector and ground.
A/T shift selector (detention switch) Ground Continuity Connector Terminal M57 14 Not existed
Is the inspection result normal?
YES
GO TO STEP 10 .
NO
Repair or replace harness.
- CHECK A/T SHIFT SELECTOR (DETENTION SWITCH)
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
Replace A/T shift selector. Refer to REMOVAL AND INSTALLATION .
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END