Malfunction Indicator Light Not Operating Properly
NOTE:
After making any repairs, perform BODY VERIFICATION TEST
under VERIFICATION TESTS.
- Perform self-test on instrument cluster. Press and hold TRIP/RESET button and turn ignition on. If Malfunction Indicator Lamp (MIL) does not turn on for 4 seconds then turn off, go to step 3 . If MIL turns on for 4 seconds then turns off, go to next step.
- Connect scan tool to Data Link Connector (DLC) located under left side of instrument panel. See Figure . Turn ignition on. Using scan tool, check for DTC. If any DTCs are present, diagnose DTCs. See DIAGNOSTIC TROUBLE CODE IDENTIFICATION table under SELF-DIAGNOSTIC SYSTEM. If no DTCs are present, go to next step.
- Turn ignition off. Remove instrument cluster and inspect MIL bulb and socket. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Replace MIL bulb and socket as necessary. If MIL bulb and socket are okay, replace instrument cluster.