LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2023 >> e-tron GT Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 34 (Assistance Systems) >> 98 Assistance Systems >> Rearview Camera System >> Rearview Camera System, Calibrating

Rearview Camera System, Calibrating

WARNING: This page is about a different car, the 2022 Audi e-tron GT and 2022 Audi RS e-tron GT. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Calibration of the rearview camera system is necessary:

Conditions

The calibration requirements must be met.

Procedure 

-- Check which hole circle the rims have.

-- On every Wheel Center Mounting: VAS6350/1A  , attach three fitting wheel bolt adapters for the wheel bolts using the Supplementary Set Audi R8: VAS6350/5  .

-- Insert the measuring paddle at both Calibration Tool - Wheel Center Mounting: VAS6350/1A  and secure with the locking nut.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC

-- Place the Calibration Tool - Wheel Center Mounting: VAS6350/1A  onto the wheel bolts on both rear wheels.

Conditions

-- Place the Calibration Tool - Wheel Center Mounting: VAS6350/1A  on the wheels so that any anti-theft wheel bolts are not connected to the wheel center mounting.

-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.

Conditions

-- Position the Calibration Tool: VAS6350A  at distance -a- to the rear wheels.

Fig 2: Positioning Calibration Device VAS 6350
GWWA96-10536Courtesy of AUDI OF AMERICA, LLC

Conditions

-- Using the bubble level (level indicator) -arrow-, bring the Calibration Unit: VAS6350A  into a level position by turning the plastic bases.

GWWN91-12608Courtesy of AUDI OF AMERICA, LLC

-- Put on the contrast glasses.

Fig 3: Identifying Laser -1- On Calibration Platform Set To Align Entire Calibration Platform With Vehicle
GWWA91-10525Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Linear Laser: VAS6350/3A  -1- on the Calibration Tool: VAS6350A  .

-- Align the Calibration Tool: VAS6350A  so that the Calibration Tool - Linear Laser: VAS6350/3A  -1- strikes the center of the emblem on the rear lid.

Measurement of the Dimension from the Calibration Tool: VAS6350A  to the Rear Wheels

-- Switch on the Calibration Tool - Spacing Laser: VAS6350/2A  .

Fig 4: The Following Display Appears -1- :
GWWN91-12610Courtesy of AUDI OF AMERICA, LLC

-- Indicator on the display -1-.

-- Display 2 displays how the Calibration Tool - Spacing Laser: VAS6350/2A  must be positioned.

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Press the corresponding button.

-- Hold the Spacing Laser: VAS6350/2A  -2- on one side of the calibration board flush to the catch bracket, as shown.

GWWN98-10007Courtesy of AUDI OF AMERICA, LLC

Conditions

-- Press the measuring button briefly.

The laser switches on.

-- The "laser beam" must strike the lower, extended part of the measurement paddle -1-.

If necessary, adjust the height of the measurement paddle -1- by using the clamping screw at the Calibration Tool - Wheel Center Mounting: VAS6350/1A  .

-- Press the measuring button for the distance measurement.

-- Note the value.

-- Repeat the measurement for the rear wheel on the opposite side of the vehicle.

Conditions

-- If the values are not equal readjust the Calibration Tool: VAS6350A  accordingly and repeat the measurements.

Conditions

Measurement of the dimension from the Calibration Tool: VAS6350A  to the Workshop Floor

-- Measure the dimension from the upper edge of the Calibration Tool: VAS6350A  to the floor, dimension -a-.

GWWN98-10008Courtesy of AUDI OF AMERICA, LLC

Conditions

-- Display -2- displays how the Calibration Tool - Spacing Laser: VAS6350/2A  must be positioned.

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Press the corresponding button.

-- Press the measuring button briefly.

-- Note the value.

Height Measurement from the Center of the Rearview Camera Lens to the Wheel Contact Surface

-- Use a commercially available measuring tape to measure the height from the center of the rearview camera lens to the wheel contact surface.

-- Write down the height measurement.

Calibration Procedure

-- Perform the calibration of the rearview camera function using the. Refer to Diagnostic Entries .

Conditions

-- Disconnect the battery charger. Refer to BATTERY, CHARGING .