LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2006 >> RL >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC >> Climate Control >> Recirculation Control Motor Test

Recirculation Control Motor Test

NOTE: Before testing, check for HVAC DTCs (see GENERAL TROUBLESHOOTING INFORMATION  ).
  1. Disconnect the 5P connector from the recirculation control motor.
    NOTE: Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
  2. Connect battery power to the No. 1 terminal of the recirculation control motor, and ground the No. 2 terminal; the recirculation control motor should run, and stop at Recirculate. If it doesn't, reverse the connections; the recirculation control motor should run, and stop at Fresh.
    Fig 1: Identifying Recirculation Control Motor Terminals
    G05496642Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. If the recirculation control motor did not run in step  2, remove it, then check the recirculation control linkage and door for smooth movement.