LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2006 >> RL >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC >> Climate Control >> Recirculation Control Motor Replacement

Recirculation Control Motor Replacement

  1. Remove the glove box (see GLOVE BOX REMOVAL/INSTALLATION ).
  2. Disconnect the 5P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
    Fig 1: Identifying Recirculation Control Motor And Fasteners
    G05496643Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.