Rear Vent Control Motor Test
NOTE:
Before testing, check for HVAC DTCs (see GENERAL TROUBLESHOOTING INFORMATION
).
- Disconnect the 5P connector from the rear vent control motor.NOTE: Incorrectly applying power and ground to the rear vent control motor will damage it. Follow the instructions carefully.
- Connect battery power to the No. 1 terminal of the rear vent control motor, and ground the No. 2 terminal; the rear vent control motor should run, and stop at Shut. If it doesn't, reverse the connections; the rear vent control motor should run, and stop at Rear Vent.
- If the rear vent control motor did not run in step 2, remove it, then check the rear vent control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the rear vent control motor (see REAR VENT CONTROL MOTOR REPLACEMENT ).
- If the linkage or door sticks or binds, repair them as needed.