Checking The Wiring
There is either a fault in the supply voltage or in the ground lead. Check the power supply cable against a ground terminal (the chassis).
HINT: If the voltage is 12 V the fault is in the ground lead. Other wise the fault is in the power supply cable.
Remedy as necessary.
Other information:
- To access or replace the control module, see UPPER ELECTRONIC MODULE (UEM)/REARVIEW MIRROR, REPLACING
- see RAIN SENSOR
- For further information about signals and other values, see SIGNAL DESCRIPTION, UPPER ELECTRONIC MODULE (UEM)
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To fault-trace the wiring and terminals, see CHECKING WIRING AND TERMINALS .
- Continue