Checking Components And Wiring
Check the resistance of the valve between the leak diagnostic unit connector terminals #3 and #4 (leak diagnostic pump side).
Check the signal cable between control module terminal #B40 (#B50) and leak diagnostic unit terminal #3. Check for a short-circuit to supply voltage.
Try a new leak diagnostic unit if no fault is found during the above fault-tracing.
Remedy as necessary.
Other information:
- see CHECKING WIRING AND TERMINALS
- For resistance values, see COMPONENT SPECIFICATIONS
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- For 5 cylinder turbocharged engines -2004, see SIGNAL DESCRIPTION
- For 6 cylinder engines -2004, see SIGNAL SPECIFICATION
- To access or replace the leak diagnostic unit, see LEAK DIAGNOSTIC PUMP, REPLACING .
- Continue
Refer to VERIFICATION