Intermittent Fault
Check the control module connector and the electrical terminal for the glow plug. Check for loose connections. See LOOSE CONNECTIONS (TERMINALS) . Check for contact resistance and oxidation. See CONTACT RESISTANCE AND OXIDATION .
Check the cable between control module terminal #1 and the glow plug terminal. Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground. Check for an intermittent short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access the glow plug, see GLOW PLUG ENGINE COOLANT HEATER, REPLACING
- With the ignition on and the glow plug electrical terminal disconnected, the voltage between the glow plug electrical terminal (control module side) and ground must be approximately 9 V
- For other values, see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to INFORMATION
OKAY: Troubleshooting has been completed.