Intermittent Fault
Check the fuel pump (FP) and the control module connectors. Check for contact resistance and oxidation.
Check the cable between control module terminal #13 and fuel pump terminal 2. Check for an intermittent open-circuit. Check for a short-circuit to ground.
Check the cable between control module #11 and water pump terminal 1. Check for an intermittent open-circuit.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access or replace the fuel pump (FP), see FUEL PUMP AUXILIARY HEATER, REPLACING
- For other values, see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to INFORMATION
OKAY: Troubleshooting has been completed.