Checking The Cable And Component
- Ignition off
- Check the connectors for the upper electronic module (UEM) and roof lamp module. Check for contact resistance and oxidation.
Remedy as necessary
- Reinstall the connectors, components etc.
- Ignition on.
Activate the general lighting: Use the VCT2000 (or appropriate scan tool).
Other information:
- To access the roof lamp switch, see INTERIOR LIGHTING, REPLACING
- To access the connector for the upper electronic module (UEM), see UPPER ELECTRONIC MODULE (UEM)/REARVIEW MIRROR, REPLACING
- see CHECKING WIRING AND TERMINALS .
Do the lamps light?
- YES
Refer to VERIFICATION
- NO
Refer to CHECKING FOR AN OPEN-CIRCUIT