Checking For Open-Circuits And Short-Circuits
Check the cable between the upper electronic module (UEM) terminal #21 and the sun roof module (SRM) terminal #4. Check for a short-circuit to ground. Check for an open-circuit. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information
- For further information about signals and other values, see SIGNAL DESCRIPTION, UPPER ELECTRONIC MODULE (UEM)
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access the sun roof control module, see CONTROL MODULE, SUN ROOF, REPLACING
- see CHECKING WIRING AND TERMINALS .
Was a fault detected?
- YES
Refer to VERIFICATION
- NO
FAULT NOT FOUND: Troubleshooting has been completed.