Checking Wiring And Connectors
Check the resistance of the fuel level sensor (left-hand side). The resistance across each sensor may vary between 12 ohms (full fuel tank) and 383 ohms (empty fuel tank).
HINT: The resistance of the fuel level sensor (left-hand side) can be measured between fuel level sensor connector terminals #5 and #6.
Check the cables between fuel level sensor connector terminal #5 and breakout box terminal #A02 (#A2). Check for a short-circuit to ground. Check for an open-circuit.
Check the ground lead between breakout box terminal #A10 (#A10) and fuel level sensor connector terminal #6. Check for an open-circuit.
Remedy as necessary.
Other information:
- For further information about signals and other values, see SIGNAL SPECIFICATION
- To access the rear electronic module (REM), see RELAY/FUSE BOX CARGO COMPARTMENT/REAR ELECTRONIC MODULE (REM), REPLACING
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access the fuel level sensor (left-hand side), see LEVEL SENSOR FUEL TANK LEFT, REPLACING
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to VERIFICATION