Checking The Power Supply And Ground At The Rear Control Module
Check the voltage to ground at rear control module terminal #B26 (#E6). The voltage must be at least battery voltage minus 3 V.
Check the control module connector. Check for contact resistance and oxidation. Check for loose connections. Check for damage carefully.
Check the wiring between rear control module terminal #B21 (#E1) and the ground terminal. Check for an open-circuit.
Remedy as necessary.
Other information:
- To access the rear control module connector, see RELAY/FUSE BOX CARGO COMPARTMENT/REAR ELECTRONIC MODULE (REM), REPLACING
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to VERIFICATION