Checking Components And Wiring
Check the cable between control module terminal #13 and fuel pump terminal 2. Check for an open-circuit. Check for a short-circuit to ground.
Check the cable between control module terminal #11 and fuel pump (FP) terminal 1. Check for an open-circuit.
Replace the fuel pump (FP) if no fault is found in the wiring.
NOTE:
Diagnostic trouble code (DTC) CEM-5F3B Water pump, signal and / or diagnostic trouble code (DTC) CEM-5F3D Combustion fan, signal may also be stored if there is a fault in the power cable.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access or replace the fuel pump (FP), see FUEL PUMP AUXILIARY HEATER, REPLACING
- For other values, see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to VERIFICATION