Checking Components And Wiring
Check the pump motor's resistance between the leakage diagnostic unit's connector #1 and #4 (against the leakage diagnostics pump).
Check the signal cable. Check for a short-circuit to ground.
Take readings between:
- Engine Control Module (ECM) #B23 (#C23) and leakage diagnostic unit #1.
Try a new leakage diagnostics unit if no defect is found during the above troubleshooting.
Remedy as necessary.
Other information
- see CONNECTING THE BREAKOUT BOX
- see SIGNAL SPECIFICATION
- see COMPONENT SPECIFICATIONS
- see LEAK DIAGNOSTIC PUMP
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to INFORMATION