Gear Shift Solenoids

Fig 1: Identifying Ohms Resistance Temperature Graph
GLL141944Courtesy of VOLVO CARS CORPORATION
Component  Remarks  Resistance (Ω) 
Shift solenoids S1, S2, S3, S4 and S5 Resistance between the solenoid pin and the solenoid sleeve or transmission housing +20°C = 11-16 Ω

For other values, see diagram. When taking readings at temperatures other than +20°C, a control reading must be taken at +20°C. This is done to check whether the resistance is correct or not.