Hesitation Upon Acceleration (TJ26091)
Reference number: TJ26091
HESITATION UPON ACCELERATION
TECHNICAL SERVICE BULLETIN
| VOLVO: | 2011 and beyond S80, XC60, XC70, XC90 |
| SECTION: | Ignition and Control System |
| GROUP: | 2800 |
| NO.: | US26091.1.0 en-US |
| Related Ref. Number(s): | VIDA, VSTG, TJ26091 |
ATTACHMENT
Vehicle Type
| Type | Eng | Eng Desc | Sales | Body | Gear | Steer | Model Year | Plant | Chassis range | Struc Week Range |
|---|---|---|---|---|---|---|---|---|---|---|
| 124 | 95 | B6324S5 | 2011-9999 | 21 | 0134001-0999999 | 201020-201216 | ||||
| 136 | 95 | B6324S5 | 2011-9999 | 21 | 0094001-0999999 | 201020-201216 | ||||
| 156 | 95 | B6324S5 | 2011-9999 | 22 | 0135000-0999999 | 201020-201216 | ||||
| 275 | 95 | B6324S5 | 2011-9999 | 21 | 0568001-0999999 | 201020-201216 |
CSC CUSTOMER SYMPTOM CODES
| Code | Description |
|---|---|
| 1Q | Driving/Poor performance/lacks power/At take off |
| AJ | Driving/Poor performance/lacks power |
| AL | Driving/Hesitates/surges/During acceleration |
DTC DIAGNOSTIC TROUBLE CODES
Text
DESCRIPTION
A hesitation upon acceleration may be felt by the customer, especially with fuel with a low octane rating. Hot ambient temperature and / or high altitude may make the situation worse. The root cause has been found to be knock limitation (ignition retardation due to knock). This applies to vehicles with engine 95 only.
PRODUCT MODIFICATION
New Engine Control Module (ECM) Software (SW) will be introduced into production during structure week 2012w16.
SERVICE
New ECM SW is now available as a service fix.
With a confirmed hesitation comlaint, perform an ECM Upgrade according to VIDA. If there are any other symptoms, for example Bank 2 misfires and/or knocking noises coming from the oil pan, please also refer to TJ 24516 - Hesitation upon acceleration.
VOLVO STANDARD TIMES GUIDE (VSTG) INFO
Operation number 36004-2 - Software ECM module upgrade - See VSTG
- Claims may be submitted under the new car warranty when there is a documented customer complaint using claim type: 01
- Labor times are valid at the time of release and are subject to change.