Checking The Wiring
Check the signal cable for the valve between control module terminal #B40 (#B50) and leak diagnostic unit terminal #3. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- see CHECKING WIRING AND TERMINALS
- For resistance values, see COMPONENT SPECIFICATIONS
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- For 5 cylinder turbocharged engines -2004, see SIGNAL DESCRIPTION
- For 6 cylinder engines -2004, see SIGNAL SPECIFICATION
- To access or replace the leak diagnostic unit, see LEAK DIAGNOSTIC PUMP, REPLACING
- Continue
Refer to VERIFICATION