Checking Components And Wiring
- Check the water pump and combustion preheater module (CPM) connectors. Check for contact resistance and oxidation. Check for damage in particular
- Check the cable between combustion preheater module (CPM) terminal #12 and water pump terminal 1. Check for an open-circuit. Check for a short-circuit to ground
- Check the cable between combustion preheater module (CPM) terminal #11 and water pump terminal 2. Check for an open-circuit.
NOTE:
Diagnostic trouble codes (DTC) CEM-5F3D and/or CEM-5F3F may also be stored if there is a fault in the power cable.
The water pump must be replaced if no faults are found in the wiring.
Remedy as necessary.
Other information
- see CONNECTING THE BREAKOUT BOX
- see SIGNAL SPECIFICATION
- see WATER PUMP ENGINE COOLANT HEATER, REPLACING
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to VERIFICATION
- Check the water pump and combustion preheater module (CPM) connectors. Check for contact resistance and oxidation
- Check the cable between combustion preheater module (CPM) terminal #12 and water pump terminal 1. Check for an intermittent open-circuit. Check for an intermittent short-circuit to ground
- Check the cable between combustion preheater module (CPM) terminal #11 and water pump terminal 2. Check for an intermittent open-circuit.
Remedy as necessary.
Other information
- see CONNECTING THE BREAKOUT BOX
- see SIGNAL SPECIFICATION
- see WATER PUMP ENGINE COOLANT HEATER, REPLACING
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to VERIFICATION