Checking Components And Wiring
Check the cable between control module terminal #8 and the signal cable for the flame sensor. Check for a short-circuit to ground.
HINT: It is difficult to differentiate between the ground lead for the flame sensor and the signal cable. Take readings on one cable at a time to check for a relevant value on either of them.
Replace the flame sensor if no fault is found in the cable.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access or replace the flame sensor, see OVERHEAT PROTECTION THERMOSTAT / FLAME SENSOR / ENGINE COOLANT TEMPERATURE SENSOR, REPLACING
- For other values, see SIGNAL SPECIFICATION .
- Continue
Refer to VERIFICATION