Checking Wiring And Connectors
Check the voltage supply cable between the upper electronic module (UEM) connector terminal #10 and movement sensor (IMS) connector terminal #1. Check for an open-circuit. Check for an intermittent open-circuit.
Also check both connectors for contact resistance and oxidation.
If no fault was found, try a new sensor.
Other information:
- For further information about signals and other values, see SIGNAL DESCRIPTION, UPPER ELECTRONIC MODULE (UEM)
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- see REAR INTRUSION SENSOR
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to VERIFICATION