Checking The Connectors
- Ignition off
- Check the fuel pump (FP) and the control module connectors. Check for contact resistance and oxidation and remedy.
Check for damage carefully
- Reinstall the components, reconnect the connectors etc.
- Ignition on.NOTE:
It is important that only the ignition is on in order for the heater to start.
- Activate the heater.
A buzzing sound should be heard from the heater.
Check the function of the heater. See ENGINE COOLANT HEATER, TEST RUNNING .
If the heater now functions, the cause of the fault was loose connections in the connectors.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access or replace the fuel pump (FP), see FUEL PUMP AUXILIARY HEATER, REPLACING
- For other values, see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS .
Does the heater operate?
- YES
OKAY: Troubleshooting has been completed.
- NO