Intermittent Fault
Check the cable between control module terminal #12 and water pump terminal 1. Check for an intermittent short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To access the control module or connect the breakout box, see CONNECTING THE BREAKOUT BOX
- To access or replace the water pump, see WATER PUMP ENGINE COOLANT HEATER, REPLACING
- With the ignition on and the water pump connector disconnected, the voltage between water pump terminal 1 (control module side) and ground should be approximately 0 V
- For other values, see SIGNAL SPECIFICATION
- see CHECKING WIRING AND TERMINALS .
- Continue
Refer to INFORMATION