Diagnostic Trouble Code (DTC) Information FSM-C100115
Condition
There is an external heating coil to prevent moisture on the camera lens or on the windshield in front of the camera.
Forward Sensing Module (FSM) controls activation/deactivation of the camera's heating coil. The heating coil does not activate spontaneously above 20°C, activation occurs via diagnostic command.
The diagnostic trouble code (DTC) is stored if the control module detects that:
- The cable for activating/deactivating heating coil has an open circuit or is short-circuited to voltage.
The control module's test for the diagnostic trouble code (DTC) starts in the event of:
- Ignition on for at least 5 seconds.
- Deactivated heating coil.
NOTE:
The control module can only detect the fault once the test has been started and the diagnostic trouble code (DTC) is stored when the conditions are met.
Substitute Value
- None.
Possible Source
- The cable is short-circuited to voltage.
- The cable has an open circuit.
Fault symptom[s]
- None.