Checking wiring and connectors
Check the control module and fuel level sensor connectors. Check for contact resistance and oxidation. Check for loose connections.
Check the signal cable between control module terminal #2A and fuel level sensor connector terminal #5. Check for an open-circuit. Check for a short-circuit to supply voltage.
Check the ground lead between control module terminal #10A and fuel level sensor connector terminal #6. Check for an open-circuit.
Other information:
- For information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To access the control module, see Integrated relay/fuse box cargo compartment/rear electronic module, replacing
- To access the fuel level sensor (left-hand side), see Left fuel gauge sensor
- See Checking wiring and terminals. Intermittent faults .
- Continue
Refer to Information