Checking the control module
- Ignition off
- Remove the relay
- Ignition on.
Check the relay coil driver circuit for a short-circuit to supply voltage by measuring the voltage at terminal #2 in the relay base.
HINT: The voltage between terminal #2 and ground should be approximately 0 V.
Remedy as necessary.
Other information
- To access and replace the relay, see Central electronic module (CEM), replacing
- For further information about the fuses and relays, see the Wiring Diagram
- See Checking wiring and terminals .
- Continue
Refer to Verification