Signal Specification
General
All values contained below are between the relevant terminal and signal ground, unless otherwise indicated in brackets.
NOTE:
It is important to connect the breakout box and check the ground terminals before taking readings.
| U= | DC voltage in volts (V) | Ulow = | Voltage approximately 0 V |
| Ubat = | Battery voltage (V) |
SIGNAL TABLE
| Connector A | ||||
|---|---|---|---|---|
| Terminal Breakout box | Terminal Control module | Signal type | Ignition on Active/Not active | Other |
| #1 | #A1 | 15 supply | U = Ubat | |
| #2 | #A2 | Communication LIN | U =5 V | |
| #3 | #A3 | Ground 31S | U=Ulow | |
| #10 | #A4 | - | ||
| #9 | #A5 | Ground 31S | U=Ulow | |
| #8 | #A6 | IR sensor | U=Ubat / 0 V | |
| #7 | #A7 | Communication CAN_H low speed network | During communication the voltage is 2.5-3.5 V | |
| #6 | #A8 | Communication CAN L low speed network | During communication the voltage is 1.5-2.5 V | |
| #5 | #A9 | Communication CAN_H low speed network | During communication the voltage is 2.5-3.5 V | |
| #4 | #A10 | Communication CAN L low speed network | During communication the voltage is 1.5-2.5 V | |
| Connector B | ||||
| Terminal Breakout box | Terminal Control module | Signal type | Ignition on | Other |
| B1 | MOST input signal | - | Optical input signal | |
| B2 | MOST output signal | - | Optical output signal | |