Checking cables: Notes
Check signal cable between control module #A47 (#A47) and camshaft position (CMP) sensor connector #2 for an open-circuit according to Open-circuit, permanent faults and for a short-circuit to ground according to Short-circuit to ground, permanent faults . Check power cable between control module #A29 (#A29) and camshaft position (CMP) sensor connector #1 for an open-circuit according to Open-circuit, permanent faults . Check the ground lead between control module #A65 (#A65) and camshaft position (CMP) sensor connector #3 for an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box .
- For component location on the B52X4 T see Location of components .
- For component location on the B6304 S see Location of components .
- For component location on the B6284 T see Location of components .
- For information about signals on 5-cylinder engines, see Signal specification .
- For information about signals on 6-cylinder engines, see Signal specification .
- Continue
Refer to Verification