Checking component and wiring
Check outside temperature sensor resistance.
Check signal cable between control module #B29 (#B39) and outside temperature sensor #1 for a short-circuit to ground according to Short-circuit to ground, permanent faults
HINT: With the ignition on and outside temperature sensor connector disconnected the voltage between #1 and ground terminal should be approximately 5V.
Remedy as necessary.
Other information:
- Connecting the breakout box/accessing the control module, see Connecting the breakout box .
- To access/replace the outside temperature sensor, see Outside temperature sensor door mirror, replacing .
- For resistance values, see Component specifications .
- For information about signals on 5-cyl, see Signal specification .
- For information about signals on 6-cyl, see Signal specification .
- Continue
Refer to Verification