Checking for a short-circuit
Check that the button has not jammed in its depressed position.
Check the cable between the upper electronic module (UEM) and the roof lamp module. Check for a short-circuit to supply voltage.
UEM-001D front left reading lamp
Control module terminal #4 and roof lamp module terminal #8A.
UEM-001E front right reading lamp
Control module terminal #16 and roof lamp module terminal #7A.
Replace the cable if a fault is found.
Other information:
- For further information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To access the roof lamp module switches:
- For -2002, see Interior lighting and upper electronic module (UEM), replacing
- For 2003-, see Interior lighting, replacing .
- With the ignition on and when the function is not activated, the voltage between terminal #8A (UEM 001D) and terminal #7A (UEM 001E) on the roof lamp unit (control module side) and ground should be 0 V
- See Checking wiring and terminals .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Replacing the component